• Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2
  • Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2
  • Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2
  • Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2
  • Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2
  • Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2

Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2

Type: Power Source Arrester
Structure: Plugable
Installation: DIN Rail
Application: AC/DC System
Size: Small
Operation Voltage: High Voltage
Samples:
US$ 9/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
  • Product Parameters
  • Packaging & Shipping
  • Company Profile
  • Manufacture of solar
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
E-15 SERIES
Shape
Module
Material
Nylon
Certification
ROHS, ISO9001, CCC
Brand
Golden or OEM
Voltage
DC 500V, 550V, 800V, DC1000V(3p) 1200V, 1500V
Us(Ka)
20ka
Imax(Ka)
40ka
Series
AC SPD, Surge Protector, Surge Protective Device
Color
Orange
Altitude
2000
Where to Use
Solar PV System
Terminal Screwa
M5
Indication
Green(Good) Red(Replace)
Class Test
II
Transport Package
Standard Export Carton
Specification
2p and 3p
Trademark
Golden or netural or customer brand
Origin
China
HS Code
8536300000
Production Capacity
50000PCS/Month

Product Description

 

Product Description

          Surge protective device 20KA-40kA Power AC/DC surge protection

Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2
         HIGH QULITY
Module design, convenient installation,with easy electric maintains operation
Built-in over current and over heat, temperature control open circuit technology

 

     EXCELLENT DESIGN
Adopt independent intelligence property right and high performance sensitivity resistance plates
Small creepage current,fast response time, remnant low voltage
With remote connection, can realize remote control. 
Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2

 

Product Parameters

Solar AC SPD
Intensity of Remote Signalling Alarm Contact
Failure indication and centralized remote signalling alarm dry contacts;
High discharge capacity and low residual voltage;
Over-temperature protection;
IP20, UL94 V0
Item AC SPD 
Code GD-M
Rated Operating Voltage Un(V~) 380V/220V
Maximum Continuous Operating Voltage Uc(V~) 275V  320V 385V 385V 385V 420V
Voltage protection Level Up(V~)kV ≤1.0 ≤1.2 ≤1.8 ≤2.0 ≤2.2 ≤2.8
Nominal Discharge Current ln (8/20s)kA 5 10 20 30 40 60
Maximum Discharge Current lmax(8/20s)kA  10 20 40 60 80 100
Response Time (ns)  <25
Test Standard  IEC61643.1, GB18802.1
Operating Environment(centigrade)  -40ºC ~+85ºC
Max Connection Line  35mm2 hard wire/35mm2 strand wire copper line
Recommended Connection Line 16mm2 hard wire/25mm2 strand wire copper line
Installation Standard Rail 35mm
Surge Protective Device Arrester Dimensions:
Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2
Solar DC SPD
The GD-M series Surge Protection are designed to protect against lightning surge voltages in photovoltaic power supply networks.

These units must be installed in parallel on the DC networks to be protected and provide common and differential modes protection. The GD-M series is available for the main operating voltages in photovoltaic: 1000 Vdc.

The use of GD-M series Surge Protection is recommended at both ends of the DC power supply line (solar panel side and inverter/converter side),

Especially if the line routing is external and long. The electrical diagram of the GD-M series is based on high energy PV equipped with specific thermal disconnectors and related failure indicators.

The SUP series is made with plug-in modules to allow a fast and easy maintenance in case of failure (disconnection from the DC network).
SUP2-PV series surge protector GD-M
PV DC specific (LEC 6614-1/EN 61643-11)  
Pole 2 pole 3 pole
Electrical Parameter  
Classifical test II II
Uoc max (V DC) 500 900
Uc (V DC) 500 1000
In(8/20)us (KA) 20 20
Imax(8/20)us (KA) 40 40
Up (KV) 2 3.8
Remote control and indication    
Indication window    
Plug-in module    
Remote signal contact    
Remote signal contact Max working volt 250V AC/30V DC 250V AC/30V DC
Max working amp 1A (250V/AC) 1A (250V/AC) 1A (250V/AC)
1A (30V DC) 1A (30V DC) 1A (30V DC)
Wiring & installation    
Wiring capacity(mm2) Hard wire 4-25 4-25
  Flexible wire 4-16 4-16
Stripping length 10 10
Terminal screwa M5 M5
Torque(Nm) Main ciruit 3.5 3.5
Remote signal contact 0.25 0.25
Protection class All profile IP40 IP40
Connection port IP20 IP20
Installation environment No obvious shock and vibration
Altitude(m) ≤ 2000 ≤ 2000
Working temperature 67 67
Relative humidity 30%-90% 30%-90%
How to install Install with H35-7.5/DIN35 stell mounting rail
Size(mm) (W*H*L) W 36 54
H 90 90
L 67.6 67.6
Weight (KG) 0.25 0.38
Nominal PV system volt 600V 100V 1200V
MCOV(UCPV) 700V DC 1170V DC 1200V DC
Max system discharge Current (8/20us) (Imax) 40KA 40KA 30KA
Volt protection leve (UP) ≤ 2.5KV ≤ 4.0KV ≤ 4.5KV
Volt protection Level at 5KA (UP) ≤ 2.0KV ≤ 3.5KV ≤ 4.0KV
Integrate fuse breaking capacity/interrupting rating 30KA/1000V DC 30KA/1000V DC 30KA/1200V DC
Technology Short-circuit interruption (SCI) overcurrent protection
Operating temperature range -40 to +80
Nominal discharge current 12.5KA
Response time (ta) <25ns
Operating state/fault indication Green (good) / Red (replace)
Mounting 35mm DIN Rail per EN 60715
Degree protection IP20
capacity 3 modules DIN 43880
Surge Protective Device Arrester Dimensions:
Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2

Packaging & Shipping

Surge Protective Device Arrester Packing List:
Name Specification Packing quantity GW/ctn Carton size
GDPS-4 DC 2P/20~40KA/DC500V 60 18.5 42*32*16.5cm
GDPS-4 DC 2P/20~40KA/DC800V 60 18.5 42*32*16.5cm
GDPS-4 DC 2P/20~40KA/DC1000V 60 19 42*32*16.5cm
GDPS-4 DC 3P/20~40KA/DC100V 40 18.3 42*32*16.5cm
GDPS-4 DC 2P/20~40KA/DC1200V 40 19.3 42*32*16.5cm
 

Packaging Details:

Customized Packing: Header card packing, Blister with card packing, Double blister packing, Canister packing, other
packing can be supplied according customers request.

Shipping:

1. By Air or by Sea for batch goods,Airport/ Port receiving;

2. Customers specifying freight forwarders or negotiable shipping methods!

Delivery Detail:
Shipped in 7 days after payment
Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2
 

Company Profile

 

   - Golden Electric Co.,Ltd ,was foundad in 2017, we are professional for make AC and DC electric items such as cable gland, isolator switch , fuse , breaker , distribution box , PV combiner box ,surge protector, Industrial plug and socket,Solar product and so on.

   - Golden has been granted ISO9001 management system certifications. The comprehensive product line has more than 1000 models which have been approved by TUV,CE,CQC,SGS,ROHS,SASO. The productsells well to UK, Spain, Portugal, Singapore, Turkey, Russia, Korea, South Africa... more than 60 countries and regions.

 
    - Golden is always striving hard to provide the best services and competitive price to all customers.

Manufacture of solar

Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2
Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2
Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2
Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2
Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2
Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2

Our Advantages

1.Best ensure 100% customer satisfaction.
2.Our products have one year guarantee.
3.Sample in design and easy to operate and maintain.
4.All electrical parts of products are made up for qualitified marterials.
5.No MOQ limited for the trial order.
6.We adopt good credit quality electrial appliances.
7.Best customer care and effcient after-sale services.
8.Don't hesitate to inquire us,we will reply you within 12 hours.

Solar House AC SPD 20ka- 40ka 2p 3p 4p Surge Protective Device for AC System Surge Protector SPD 275V 385V 420V T1+T2

FAQ

 

Q1: If I'm interested in your Solar SPD when I can receive your quotation and detail information after send the enquiry?

A:All your enquiry will be replied in 8hours.

Q2:Your Solar SPD seems perfect but what's the difference between you and other suppliers?Because I find some cheaper price from others!

A: Our DC SPD is special for Solar system all the parts in the SPD are high quality customized.Not all the DC SPD are Solar SPD!

Q3:Can I get a sample before the order because I really don't how is your DC SPD quality?

A:Of course!We also think sample order is the best way to build the trust.

 Q4:How's the delivery?Because I really need them is urgently?

A:For sample order 3~7days will be no problem.And for regular order we promise in 15days.

Q5:How's the warranty  period for your DC SPD?

A:We offer one year warranty for our customer.

How to contact us 
 Send your Inquiry Details in the Below, please Click "sendNow!
 Good price and sample are waiting for you.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now