ATS700 series ATS controller is intelligent dual-supply module with configurable function, automatic measurement ,LCD display, and digital communication. It combines digital, intelligence and networking. Automatic measurement and control can reduce incorrect operation. It is an ideal option for ATS.
The powerful Microprocessor contained within the unit allows for precision voltage (2ways-3phase) measuring and make accurate judgment, in addition, the corresponding digital output port will active when there id over /under voltage, over/under frequency, loss of phase and other abnormal condition occurs. This controller has full consideration in various application of ATS (automatic transfer system) and can be directly used for PC ATS,CB ATS,CC ATS etc. It has compact structure, advance circuits,simple wiring and high reliability, and can be widely used in electrical devices,automatic control and testing system of electric power, telecommunications,petroleum,coal,metallurgy,railways,municipal administration,intelligent building etc.
Items | Content | ||
Operating Voltage | 1.DC 8.0V~35.0V, continuous power supply 2.AC90V~280V during AC power supply L1N1/L2N2 (HAT700B/HAT700BI/HAT700S) |
||
Power Consumption | <5W( standby mode:≤2W) | ||
AC Voltage Input | AC system | ||
3P4W(L-L) | (80~625)V | (80~480)V | |
3P3W(L-L) | (80~625)V | (80~625)V | |
1P2W(L-L) | (50~360)V | (50~280)V | |
2P3W(A-B) | (80~625)V | (80~480)V | |
Rated Frequency | 50/60Hz | ||
Close Relay Output | 16A AC250V Volts free output | ||
Auxiliary Relay Output | 16A/7A AC250V Volts free output | ||
Digital Input | GND(B-) connect is active | ||
Communication | RS485 isolated interface,MODBUS Protocol | ||
Case Dimensions | 197mm x 152mm x47mm | ||
Panel Cutout | 186mm x141mm | ||
Working Conditions | Temperature: (-25 ~ +70)ºC Relative Humidity: (20~93)%RH |
||
Storage Condition | Temperature: (-25 ~ +70)ºC | ||
Protection level | IP55,when water proof gasket ring inserted between panel and housing | ||
Insulation Strength | Apply AC2.2kV voltage between high voltage terminal and low voltage terminal, The leakage current is not more than 3.5mA within 1min |
Indicator Type | Description |
Alarm | Slow flashing (1time per sec) when warn alarm occurs Fast flashing (5 times per sec) when fault alarm occurs |
Running | Flash when module countdown running (1time per sec) |
S1 Powe Normal | It is light on when S1 is normal, flashing when S1 is abnormal (1time per sec), off when there is no S1 power |
S1 Close Status | It is light on when S1 close input is activated |
S2 Power Normal | It is light on when S2 is normal, flashing when S2 is abnormal (1time per sec), off when there is no S2 power |
S2 Close Status | It is light on when S2 close input is activated |
Manual Mode | It is light on when the module is manual mode |
Auto Mode | It is light on when the module is in Auto mode |
Generator Start | It is light on when the start signal is be intiated |